Boiling Water Reactor (BWR). Startup: disable RHR, withdraw rods, enable RCP, FWP, CND, CCP, HPFH, disable DA BY. On steam generation, enable TB IN and disable TB BY. Makeup as needed. Shutdown: enable RHR, disable RCP, SCRAM. Emergency: LPCI, RCIC, SLC
nuclear reactor boiling realistic steam turbine generator

Comments

  • reactor_
    reactor_
    28th June
    either way great build +1
  • reactor_
    reactor_
    28th June
    also you could try to remake it with the addition of heat pipes in v100, btw your condenser tends a LOT to boil since it really can't take heat away whitout the cooling tower boiling first to take it, so you kind of need to improve that
  • pickle4L17
    pickle4L17
    27th Sep 2025
    most realistic reactor out there
  • Perc
    Perc
    29th Aug 2025
    i have found this again, lets friggin go!!
  • pickle4L17
    pickle4L17
    28th Jul 2025
    this is impressive
  • ArandomTPTGuy
    ArandomTPTGuy
    13th Jul 2025
    *experience from RBWR like dornog has
  • ArandomTPTGuy
    ArandomTPTGuy
    13th Jul 2025
    the preaheat and DA steam inputs dont get much but based on experience they should get alota steam, a DAing condenser as dornog said could just remove the DA issue as then the DA has steam from bypass/turbine since its in a condenser
  • Riches8407
    Riches8407
    12th Jul 2025
    Thanks dornog :))
  • dornog70
    dornog70
    11th Jul 2025
    also, most BWR typically do not have dearators. but deaerating condensers.
  • dornog70
    dornog70
    11th Jul 2025
    This is a cool concept i like it, would be nice if there were actual heat exchangers for RHR and feedwater heating.